TECHNICAL INFORMATION


  • E-Beam Source:

    Radiation Dynamics Inc. Model 1500/50/4
  •  
  • Acceleration Voltage:

    1500 Kilovolts (1.5 Mev)
  •  
  • Beam Current:

    40 Milliamps
  •  
  • Scan Horn Width (beam window):

    48" (121.9 cm)
  •  
  • Product Capability:

    Thin wall tubing from .005" to .125" OD and Heat shrinkable tubing from .012 to .125" OD
  •  
  • Line Speed:

    General tubing to 350 FPM; Medical tubing to 350 FPM
  •  
  • Treatment Room Tooling:

    Two motor driven polished aluminum drums are speed controlled and follow the beam current. Maximum number of passes under the scan horn for tubing greater than .12" (30.5 cm) OD is 33. Tubing diameters less than .12" can pass up to 121 times under the beam window
  •  
  • Payoff Equipment:

    Viteck Model MPO-36-5 shaftless payoff for smaller spools. Speed controlled by micro-dancer or light weight dancer with
    6" (15.2 cm) sheaves
  •  
  • Take-Up Equipment:

    Viteck Model MPO-36-5 for small spools. Ionizing static eliminators are available on all take-ups.